Article CF-PEEK vs. Titanium Dental Implants: Stress Distribution and Fatigue Performance in Variable Bone Qualities(MDPI, 2025) Polat Sagsoz, Nurdan; Murat, Fahri; Gul, Sema Nur Sevinc; Sensoy, Abdullah Tahir; Kaymaz, IrfanThis study aims to evaluate the biomechanical behavior of titanium and carbon fiber-reinforced polyetheretherketone (CF-PEEK) dental implants under varying bone densities and loading conditions using finite element analysis (FEA). A single-tooth mandibular molar implant system was modeled, comprising titanium or CF-PEEK abutment and fixture, and surrounding bone structures with four configurations: (I) fully cortical bone, (II) 2 mm cortical layer with trabecular bone, (III) 1 mm cortical with high-density trabecular bone, and (IV) 1 mm cortical with low-density trabecular bone. Vertical and oblique static loads of 100 N were applied to simulate masticatory forces. FEA results revealed that titanium implants exhibited higher von Mises stress values in the implant and abutment under oblique loading, exceeding 400 MPa, while CF-PEEK components showed reduced stress but significantly higher strain levels. Cortical and trabecular bone surrounding CF-PEEK implants received more uniform stress distribution, potentially minimizing stress shielding effects. However, fatigue life analyses indicated that CF-PEEK abutment and screw components were more susceptible to mechanical failure under oblique loads, particularly in low-density bone models. In conclusion, CF-PEEK implants offer a more physiological load transfer to bone and reduced stress shielding compared to titanium. However, their structural reliability under complex loading, especially in low-quality bone conditions, requires careful consideration. These findings support the potential use of CF-PEEK in select clinical scenarios but highlight the need for further material and design optimization.Article Evaluation of Biomechanical Effects of Mandible Arch Types in All-On and All-On Dental Implant Design: A 3D Finite Element Analysis(MDPI, 2025) Gul, Sema Nur Sevinc; Murat, Fahri; Sensoy, Abdullah TahirThis study evaluates the biomechanical effects of different implant configurations in various mandibular arch types using finite element analysis (FEA). Stress distribution and deformation patterns were analyzed under different loading conditions in square, U-shaped, and V-shaped arches. The results indicate that increasing the number of implants generally reduces cortical bone stress, particularly in U and V arches, while implant-level stress tends to increase. Under molar loading, cortical bone stress in the square arch decreased by 16.9% (from 90.61 MPa to 75.27 MPa) with the All-on-5 system, while implant stress in the V arch dropped by 46.26% (from 142.35 MPa to 76.5 MPa). Additionally, the cantilever effect in All-on-4 configurations resulted in higher stress on the prosthesis and implants, particularly in V arches. While the All-on-5 system provided better load distribution, the study highlights the importance of optimizing implant positioning based on mandibular anatomy. Despite limitations such as the use of static forces and standardized arch types, these findings offer valuable insights into the biomechanical performance of full-arch implant rehabilitations, supporting future clinical applications and research.