Kılıç, MahmutMaali, MahyarAydın, Abdulkadir CuneytMaalı, Merve Sagıroglu2026-03-262026-03-2620222149-802410.20528/cjsmec.2022.04.001https://doi.org/10.20528/cjsmec.2022.04.001https://search.trdizin.gov.tr/en/yayin/detay/1156448/experimental-study-on-the-rotation-capacity-of-bolted-and-welded-beam-to-column-connection-using-cold-formed-steel-sectionshttps://hdl.handle.net/20.500.14901/4251This paper investigates new bolted and welded beam-to-column connection types on the cold-formed steel sections (CFS) and their behaviors determined using full-scale experiments. This study aimed to analyze the influence of weld/bolt connections based on CFS profile and failure modes to provide the necessary data for improving Eurocode 3. In contrast, the rotation and ductility of a joint of the welded connection are lower than the bolted connection. Thus, the bolted connection exhibits a semi-rigid behavior‒also, the energy dissipation capacity values in the bolted connection are bigger than welded connection. Thus, the bolded connection has a semi-rigid be-havior. Also, model failure is determined by the type of connection (bolted and weld-ed). The rotation and ductility of a joint of the welded connection are lower than the bolted connection. Thus, the bolted connection exhibits a semi-rigid behavior‒also, the energy dissipation capacity values in the bolted connection are bigger than welded connection. Furthermore, the specimens of the welded connection have rigid behav-ior in the failure modes.trinfo:eu-repo/semantics/openAccessMühendislikMakineMalzeme BilimleriÖzellik Ve TestPolimer BilimiMühendislikKimyaExperimental Study on the Rotation Capacity of Bolted and Welded Beam-to Connection Using Cold-Formed Steel SectionsArticle