A Novel Method for Improving Plasma Nitriding Efficiency: Pre-Magnetization by DC Magnetic Field

Loading...
Publication Logo

Date

2017

Authors

Kovaci, Halim
Yetim, Ali Fatih
Bozkurt, Yusuf Burak
Celik, Ayhan

Journal Title

Journal ISSN

Volume Title

Publisher

World Scientific Publ Co Pte Ltd

Open Access Color

OpenAIRE Downloads

OpenAIRE Views

Research Projects

Journal Issue

Abstract

In this study, a novel pre-magnetization process, which enables easy diffusion of nitrogen, was used to enhance plasma nitriding efficiency. Firstly, magnetic fields with intensities of 1500G and 2500G were applied to the untreated samples before nitriding. After the pre-magnetization, the untreated and pre-magnetized samples were plasma nitrided for 4 h in a gas mixture of 50% N-2-50% H-2 at 500 degrees C and 600 degrees C. The structural, mechanical and morphological properties of samples were examined by X-ray diffraction (XRD), scanning electron microscopy (SEM), microhardness tester and surface tension meter. It was observed that pre-magnetization increased the surface energy of the samples. Therefore, both compound and diffusion layer thicknesses increased with pre-magnetization process before nitriding treatment. As modified layer thickness increased, higher surface hardness values were obtained.

Description

Yetim, A Fatih/0000-0002-4314-6830; Bozkurt, Yusuf Burak/0000-0003-3859-9322; Çelik, Ayhan/0000-0002-8096-0794; Kovacı, Halim/0000-0002-9053-3593

Keywords

Plasma Nitriding, Magnetic Field, Magnetization, Pre-Magnetization, Ferromagnetic Material

Fields of Science