Bilgilendirme: Kurulum ve veri kapsamındaki çalışmalar devam etmektedir. Göstereceğiniz anlayış için teşekkür ederiz.
 

Examination of the Damage Limits of a Historical Mosque, Konya Sultan Selim Mosque Example

dc.contributor.author Kocaman, Irfan
dc.contributor.author Kazaz, Ilker
dc.date.accessioned 2026-03-26T15:02:32Z
dc.date.available 2026-03-26T15:02:32Z
dc.date.issued 2024
dc.description Kocaman, İrfan/0000-0002-1774-7114; Kazaz, İlker/0000-0002-3885-1885 en_US
dc.description.abstract The idealized global base shear force-top displacement relationship of the mosque was determined by drawing a backbone curve that bounds the force-displacement point values (F, D) representing critical actions, such as maximum force, maximum displacement, cyclic unloading paths, initiation and end of strength and stiffness reduction on the hysteresis curves from time-history analysis. Two different material parameters were employed in the analyses to account for the variation in material properties. Values from the linear response region were also taken to clarify the initial stiffness. In addition, the selected (F, D) points include almost all the values in the cycle in which the mosque is considered to have collapsed. Failure was decided by evaluating the load-deformation hysteresis curves and strain values (damage) on the finite element model. The backbone curve was idealized in three-linear form and damage limits of historical Sultan Selim mosque were defined on this curve (Figure A).Purpose:This paper presents the details of the seismic performance evaluation of the historical Konya Karapinar Sultan Selim mosque. The effect of variation in material properties on the seismic performance of historical mosques is examined by employing possible lower and upper bound values of modulus of elasticity (E). It is aimed to determine the reliability of existing damage limits on masonry structures.Theory and Methods: A detailed finite element model of the historical Konya Sultan Selim mosque was created. For modulus of elasticity E=200fc and E=750fc were assigned to finite element models. Nonlinear time-history analyzes were carried out under five different ground motions. The force-drift ratio curves of the mosque were idealized as defined in Figure A. The damage limits for each performance levels of the mosque were determined.Results: The calculated drift ratio limits were found to be lower than the limits recommended in the codes. The results of structural analyses available in the literature also indicate to lower displacement capacity of masonry structures than the collapse limits given in codes. This indicates that existing code limits provides unsafe prediction of seismic performance of masonry mosque. Conclusion: The proposed approach in this study should be applied on different historical mosques to determine more generalized damage limits. It is also noted that the seismic behavior and damage limits of historical mosques are different from other masonry structures. en_US
dc.identifier.doi 10.17341/gazimmfd.1161378
dc.identifier.issn 1300-1884
dc.identifier.issn 1304-4915
dc.identifier.scopus 2-s2.0-85174146998
dc.identifier.uri https://doi.org/10.17341/gazimmfd.1161378
dc.identifier.uri https://search.trdizin.gov.tr/en/yayin/detay/1238560/tarihi-bir-caminin-hasar-sinirlarinin-irdelenmesi-konya-sultan-selim-cami-ornegi
dc.identifier.uri https://hdl.handle.net/20.500.14901/3617
dc.language.iso en en_US
dc.publisher Gazi Univ, Fac Engineering Architecture en_US
dc.relation.ispartof Journal of the Faculty of Engineering and Architecture of Gazi University en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Sultan Selim Mosque en_US
dc.subject Historical Masonry Mosque en_US
dc.subject Seismic Performance en_US
dc.subject Finite Elements en_US
dc.subject Dynamic Analyses en_US
dc.title Examination of the Damage Limits of a Historical Mosque, Konya Sultan Selim Mosque Example en_US
dc.type Article en_US
dspace.entity.type Publication
gdc.author.id Kocaman, İrfan/0000-0002-1774-7114
gdc.author.id Kazaz, İlker/0000-0002-3885-1885
gdc.author.scopusid 57202904002
gdc.author.scopusid 12139355400
gdc.author.wosid Kocaman, İrfan/Hir-8665-2022
gdc.author.wosid Kazaz, İlker/Aaj-5676-2021
gdc.description.department Erzurum Technical University en_US
gdc.description.departmenttemp [Kocaman, Irfan; Kazaz, Ilker] Erzurum Tech Univ, Fac Engn & Architecture, Dept Civil Engn, TR-25050 Erzurum, Turkiye en_US
gdc.description.endpage 64 en_US
gdc.description.issue 1 en_US
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
gdc.description.scopusquality Q3
gdc.description.startpage 51 en_US
gdc.description.volume 39 en_US
gdc.description.woscitationindex Science Citation Index Expanded
gdc.description.wosquality Q3
gdc.identifier.trdizinid 1238560
gdc.identifier.wos WOS:001058089000005
gdc.index.type Scopus
gdc.virtual.author Kocaman, İrfan
gdc.virtual.author Kazaz, İlker
relation.isAuthorOfPublication 63f70feb-c1f6-4011-b5b0-16f7a9f8cdd0
relation.isAuthorOfPublication a8f22cc3-684b-495f-b5f5-ef4e4e5771ae
relation.isAuthorOfPublication.latestForDiscovery 63f70feb-c1f6-4011-b5b0-16f7a9f8cdd0

Files