Abstract
In this study, the effect of plasma nitriding treatment on structural, wear, corrosion and tribocorrosion properties of different type Hardox steels (400, 450 and 500 type) was investigated using X-ray diffraction, microhardness tester, scanning electron microscope, 3D profilometer and reciprocating wear tester coupled with electrochemical corrosion cell. The plasma nitriding treatments were performed in 50%N-2-50%H-2 gas mixture at 500 degrees C for 1 and 4 h. The tribological tests were carried out in dry and open circuit potential conditions at 10 N normal force in 3.5% wt. NaCl aqueous solution at room temperature. Nitriding changed the electrochemical degradation mechanism of surface to pitting corrosion. Plasma nitriding time of 1 h significantly improved the corrosion and wear resistance of the Hardox steels.
Description
Çelik, Ayhan/0000-0002-8096-0794; Yildiz, Fatih/0000-0003-4475-5379
Keywords
Plasma Nitriding, Tribocorrosion, Wear, Hardox Steel
Fields of Science
Citation
WoS Q
Q1
Scopus Q
Q1
Source
Tribology International
Volume
120
Issue
Start Page
434
End Page
445